Last Modified: Jan 16, 2021
MFG Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC | DAC |
TEB122010WL |
2 | 2 | 5 | E | |||
TEB122010WL |
2 | 1 | C | A | 6 | ||
TE122010WL |
2 | 2 | 3 | E |
Item Name: | CIRCUIT BREAKER |
Federal Supply Class (FSC): | 5925 |
NIIN: | 00-006-1305 (000061305) |
Definition: | A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller. |
NMF Description: | CIRCUIT BREAKER/SWITCH NOI |
Federal Supply Class (FSC) |
Circuit Breakers | |
Actuator Function |
Trip-reset | CPRW |
Actuator Position Designation |
At pole one | CPRX |
Body Height |
3.380 inches nominal | ADAU |
Body Length |
6.310 inches nominal | ADAQ |
Body Style |
Multipole-single actuator type | AAQL |
Body Width |
2.750 inches nominal | ADAT |
Boss Height |
0.250 inches nominal | AJEC |
Case Material |
Plastic | ADTV |
Center To Center Distance Between Terminals Parallel To Length |
5.250 inches nominal | AEBP |
Center To Center Distance Between Terminals Parallel To Width |
1.380 inches nominal | AEBQ |
Circuit Protection Type |
Overcurrent all locations | CPRH |
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width |
1.380 inches nominal | AEHA |
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length |
4.880 inches nominal | AEBY |
Frequency In Hertz |
60.0 all locations | FREQ |
Maximum Continuous Load Current Rating Per Pole |
10.0 amperes ac all locations and 10.0 amperes dc all locations | CPLM |
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps |
1000.0 ac all locations and 5000.0 dc all locations | CPRG |
Mounting Facility Type And Quantity |
2 threaded hole and 2 unthreaded hole | AXHR |
Nominal Thread Size |
0.138 inches | CQJX |
Operating Voltage Type And Rating Per Pole In Volts |
240.0 ac all locations and 250.0 dc all locations | CPRF |
Storage Type |
General purpose warehouse | BBRG |
Inclosure Protection Type For Which Designed |
Fungus resistant | CQXF |
Main Contact Tripping Mechanism Type |
Trip free | CPRR |
Manual Actuator Type And Quantity |
1 toggle | CPRT |
Reset Method |
Manual | CPRQ |
Pole Quantity |
2 | AKPX |
Terminal Type And Quantity |
4 compression | TTQY |
Thread Quantity Per Inch |
32 | CMLP |
Thread Series Designator |
Unc | THSD |
Trip Delay Time In Seconds Per Rated Continuous Current |
28.000 minimum at 200 pct all locations and 85.000 maximum at 200 pct all locations | CQWN |
Trip Release Ambient Temp Rating |
40.0 deg celsius nominal all locations | CRCF |
Trip Release Characteristic |
Instantaneous all locations and time delay all locations | CPRL |
Trip Release Method |
Thermal-magnetic all locations | CPRJ |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent |
135.0 all locations | CPRN |
Unthreaded Mounting Hole Diameter |
0.266 inches nominal | AEBV |
Schedule B | Sch. B Description | Demilitarization | Classification | ITAR Regulation |
---|---|---|---|---|
8536200040 | Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi | Non-usml/non-ccli - no demil or dod tsc required. department of commerce may impose licensing requirements to certain destinations. (note 9). | Unclassified | Not ITAR Controlled |
Country / Entity Name | MOE | |
---|---|---|
![]() |
Defense Logistics Agency | ZZ |
Code Description | Value | Meaning |
---|---|---|
HMIRS | P | Indicates there is no information in the hmirs. the nsn is in a fsc in table ii of fed std 313 and a msds may be required by t |
Precious Metals Indicator | U | Precious metal content is unknown |
Criticality Code | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Code Description | Code | Value | Meaning |
---|---|---|---|
NMF Description | NMFC | 061300 | Circuit Breaker/switch Noi |
Less than a truck load rating | LTL | P | 77.5 |
Water Commodity | WCC | 658 | Electrical appliances, small |
Type of Cargo | TCC | Z | No special type of cargo code applicable |
Special Handling | SHC | 9 | Other or no special handling required (sh) |
Air Dimension Code | ADC | A | Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
Air Commodity | ACC | H | Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
Air Special Handling | ASH | Array | No special handling required. |
5925-00-006-1305, A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Supply Class (FSC) | NSN Assignment | NIIN | Item Name Code (INC) |
---|---|---|---|
5925 | Jun 21, 1972 | 000061305 | 00136 (Circuit Breaker) |
TEB122010WL | Cage Code 03497 |
TEB122010WL | Cage Code 60969 |
TE122010WL | Cage Code 60969 |
COUNTRY CODE: | 00 |
CIIC: | U |
DML: | A |
HMIC: | P |
MGMT CTRL: | ------- |
SOS: | SMS |
INC: | 136 |
WEAPON SYSTEM: | KILAUEA CLASS T-AE 26 |
AAC: | J |
CRITL CODE: | X |
DEMIL CODE: | A |
S A: | DN |
MGMT CTL: | ------- |
NIIN ASGMT: | 21-JUN-72 |
QUP: | 0 |
SLC: | 0 |
UI: | EA |
CAGE: | 60969 |
RNCC: | 5 |
RNVC: | 2 |
Cognizance | 9B – Naval inventory control point, mechanicsburg |
Special Material | |
Requisition Restriction | |
Special Material Content |
Cognizance (COG) | Identifies the inventory manager (IM) and inventory control point (ICP). |
Special Material (SMIC) | Categorizes material on the basis of requirements for source or quality control, technical design, or configuration control, procurement, stocking and issue control, special receipt, inspection, testing, storage, or handling |
Req. Restriction (IRRC) | Item requisition instructions. |
Special Material (SMCC) | Indicated that an item represents or contains peculiar material requiring special treatment, precautions, or management. |