Last Modified: Jan 15, 2021
MFG Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC | DAC |
D6760-17-10 |
2 | 2 | 5 | 5 | |||
BACC182L10A |
2 | 9 | 5 | E | |||
6752-304-10 |
2 | 2 | 3 | 5 |
Item Name: | CIRCUIT BREAKER |
Federal Supply Class (FSC): | 5925 |
NIIN: | 00-001-5942 (000015942) |
Definition: | A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller. |
NMF Description: | FUSES NOI IN BOXES |
Federal Supply Class (FSC) |
Circuit Breakers | |
Actuator Function |
Trip-reset | CPRW |
Actuator Position Designation |
At pole two | CPRX |
Body Height |
2.125 inches maximum | ADAU |
Body Length |
2.200 inches maximum | ADAQ |
Body Style |
Multipole-single actuator type | AAQL |
Body Width |
2.250 inches maximum | ADAT |
Bushing Length |
0.220 inches minimum and 0.280 inches maximum | ABXD |
Case Material |
Plastic | ADTV |
Center To Center Distance Between Terminals Parallel To Length |
1.471 inches minimum and 1.501 inches maximum | AEBP |
Center To Center Distance Between Terminals Parallel To Width |
0.735 inches minimum and 0.751 inches maximum | AEBQ |
Circuit Protection Type |
Overcurrent all locations | CPRH |
Distance Between Centerlines Of Mounting Facilities Parallel To Body Length |
1.780 inches minimum and 1.840 inches maximum | AEBY |
Distance Between Centerlines Of Mounting Facilities Parallel To Body Width |
0.735 inches minimum and 0.751 inches maximum | AEHA |
Frequency In Hertz |
400.0 all locations | FREQ |
Maximum Continuous Load Current Rating Per Pole |
10.0 amperes ac all locations | CPLM |
Maximum Interrupting Capacity Current Type And Rating Per Pole In Amps |
1500.0 ac all locations | CPRG |
Mounting Facility Type And Quantity |
6 threaded hole | AXHR |
Nominal Thread Size |
0.138 inches | CQJX |
Operating Voltage Type And Rating Per Pole In Volts |
200.0 ac all locations | CPRF |
Fragility Factor |
Moderately rugged | AFJN |
Precious Material |
Silver | PRMT |
Storage Type |
General purpose warehouse | BBRG |
Unpackaged Unit Weight |
0.500 pounds | PKWT |
Inclosure Protection Type For Which Designed |
General purpose | CQXF |
Internal Trip Release Configuration |
Series trip all locations | CPSM |
Main Contact Tripping Mechanism Type |
Trip free | CPRR |
Manual Actuator Type And Quantity |
1 push-pull | CPRT |
Reset Method |
Manual | CPRQ |
Pole Quantity |
3 | AKPX |
Precious Material And Location |
Terminal surfaces silver | PMLC |
Terminal Type And Quantity |
6 screw | TTQY |
Test Data Document |
81205-bacc182l10a drawing (this is the basic governing drawing, such as a contractor drawing, original equipment manufacturer drawing, etc.; excludes any specification, standard or other document that may be referenced in a basic governing drawing) | TEST |
Thread Quantity Per Inch |
32 | CMLP |
Thread Series Designator |
Unc | THSD |
Trip Delay Time In Seconds Per Rated Continuous Current |
10.000 minimum at 200 pct all locations and 65.000 maximum at 200 pct all locations | CQWN |
Trip Release Ambient Temp Rating |
25.0 deg celsius nominal all locations | CRCF |
Trip Release Characteristic |
Time delay all locations | CPRL |
Trip Release Method |
Thermal all locations | CPRJ |
Ultimate Trip Rating Of Continuous Current Rating Per Pole In Percent |
150.0 all locations | CPRN |
Schedule B | Sch. B Description | Demilitarization | Classification | ITAR Regulation |
---|---|---|---|---|
8536200040 | Automatic circuit breakers, for a voltage not exceeding 1,000 v, nesoi | Non-usml/non-ccli - no demil or dod tsc required. department of commerce may impose licensing requirements to certain destinations. (note 9). | Unclassified | Not ITAR Controlled |
Country / Entity Name | MOE | |
---|---|---|
![]() |
Defense Logistics Agency | ZZ |
Code Description | Value | Meaning |
---|---|---|
HMIRS | P | Indicates there is no information in the hmirs. the nsn is in a fsc in table ii of fed std 313 and a msds may be required by t |
Precious Metals Indicator | S | Item contains silver. |
Criticality Code | X | The item does not have a nuclear hardened feature or any other critical feature such as tolerance, fit restriction or application. |
Code Description | Code | Value | Meaning |
---|---|---|---|
NMF Description | NMFC | 061300 | Circuit Breaker/switch Noi |
Less than a truck load rating | LTL | P | 77.5 |
Water Commodity | WCC | 658 | Electrical appliances, small |
Type of Cargo | TCC | Z | No special type of cargo code applicable |
Special Handling | SHC | 9 | Other or no special handling required (sh) |
Air Dimension Code | ADC | A | Shipment is not a consolidation and does not exceed 84 inches in any dimension. |
Air Commodity | ACC | H | Instruments/equipment/supplies for radio, communications, electrical, laboratory, etc. (includes signal corps) |
Air Special Handling | ASH | Array | No special handling required. |
5925-00-001-5942, A device with means other than fuses for automatically opening the circuit in which it is installed when the current varies from the predetermined value for which the device is set. may include provisions for manual operation. at least one set of contacts must be in series with the actuating element(s). a combination of semiconductor and passive devices may be used in lieu of contacts. for automatically operated items in which the actuating (tripping) element and contacts are not in series, see relay (as modified). for items which are operated both manually and automatically but the actuating elements and contact are not in series, see relay-switch. excludes circuit breaker box and magneto "breaker" assemblies. see also switch (as modified); and controller.
Supply Class (FSC) | NSN Assignment | NIIN | Item Name Code (INC) |
---|---|---|---|
5925 | Sep 29, 1972 | 000015942 | 00136 (Circuit Breaker) |
BACC182L10A | Cage Code 81205 |
6752-304-10 | Cage Code 82647 |
D6760-17-10 | Cage Code 82647 |
COUNTRY CODE: | 00 |
CIIC: | U |
DML: | A |
HMIC: | P |
MGMT CTRL: | SF9EH-N |
SOS: | SMS |
INC: | 136 |
WEAPON SYSTEM: | JOINT STARS TARGET RADAR SYSTEM |
AAC: | J |
CRITL CODE: | X |
DEMIL CODE: | A |
S A: | DS |
MGMT CTL: | SF9EH-N |
NIIN ASGMT: | 29-SEP-72 |
QUP: | 0 |
SLC: | 0 |
UI: | EA |
CAGE: | 82647 |
RNCC: | 5 |
RNVC: | 2 |
Fund | SF – Stock fund applicable to items managed for the air force by the respective inventory control point. |
Budget | 9 – Air force decentrally managed |
Material Management | EH – Electronic components (engineering support at the 88th ose/oss) |
Price Validation | N – The current standard price in the catalog management data (cmd) has not been analyzed or coded for lp/lm. -the price has not been analyzed or reviewed for accuracy. -zop or standard price challenges are permissible, but must be supported with adequate justification. however, if coded for local purchase (lp) or fabrication/manufacture as indicated with an (lm) acquisition advice code of l" or "f", the case must be evaluated locally where purchased or fabricated." |
Fund | A two position code that classifies an item into categories in terms of funding and budgeting. |
Budget | Identifies investment items to budget programs from which item is funded. |
Material Management | Identifies an item of supply to be managed by a specific activity manager. |
Price Validation | Indicates validity of the recorded unit price. |